One eSTAR, from drafted to signed
Veltara Medical is filing a Traditional 510(k) for the VLT-Flow 80 Subcutaneous Infusion Set — six models, product code FPA, 21 CFR 880.5440, Class II — against the Halvern SoftPort 90, K231592. Target submission: 20 Oct. Here is what happens next, screen by screen, in the working solution.
- 0113 Oct, morning
The whole submission, and what is left, on one screen
Nadia Brennan · Regulatory affairs specialist, devicesNadia owns the VLT-Flow 80 eSTAR v6.1: 22 of 22 sections drafted, 46 attachments, target 20 Oct. The preflight last ran on 12 Oct and the draft has had 14 edits since, so its 31 checks sit grey in eight groups — from submission and administration to declarations — with one light at the end: Ready to submit.
On the submission strip: “FDA screens it within 15 days · if it fails, up to 180 days on hold.”
- 02Predicate
The device beside its predicate, row by row
Predicate comparerThe comparer read the predicate's 510(k) Summary and the design history file and laid out 17 rows: 11 the same, 6 different. Each difference carries the report that answers it. The FEP cannula against the predicate's PTFE is answered by biocompatibility testing of the finished device (TR-0412) and kink and joint-strength testing (TR-0418), and the sentence for Section 8 is already drafted.
TR-0418: “0 of 60 FEP cannulae occluded after 72 h bent at 90°; acceptance: 0 of 60.”
- 036–9 Oct
A shelf-life claim with no report behind it
Nadia Brennan and the Predicate comparerThe draft claimed 36 months, like the predicate. On 6 Oct the comparer flagged that 36 months had no report behind it: packaging integrity and accelerated aging report TR-0433 supports 24. Nadia chose to claim 24 months rather than wait for real-time data, and on 9 Oct the drafter changed it in the description, the labels, Section 12 and the Summary. The gap is closed.
TR-0433: “Accelerated aging to ASTM F1980-21 supports a labeled shelf life of 24 months.”
- 04Sections
Every sentence cites the design file, a report or the label
Section drafterEach of the 22 sections was drafted from the design history file, 9 test reports and the labeling; 17 of 22 are approved. Section 11, Sterility, states the method — ethylene oxide, SAL 10⁻⁶, at Lakeview Sterilization Services — and the residuals and endotoxin results, each with its citation. Its validation sentence cites ISO 11135-1:2007.
The drafter never writes a claim without a source and never answers “N/A” without the reason.
- 05One click
“Run preflight” — 31 checks, the way FDA screens
Preflight checker · Standards matcher · Predicate comparerThe agents read 22 sections and 46 attachments in 1.4 s, cross-checked the facts that repeat — 6 model numbers, the product code, shelf life and indications across 31 documents — in 2.2 s, tied the 6 differences to their reports and matched 14 standards to FDA's recognised list. Each line turns green as it is checked.
“Matched 14 standards to FDA's recognised list — ISO 11135 cited at a withdrawn edition.”
- 0630 of 31
Line 22 stays red, with the fix ready
Preflight checkerSterilization cites a withdrawn edition of ISO 11135: ISO 11135-1:2007 appears in Section 11, para 2 and Section 4, row 7, while FDA recognises ISO 11135:2014 + Amd 1:2018. The wrong edition came from the 2019 eSTAR of the VLT-Flow 60, reused as a starting point. The ready light reads “Not ready yet”.
The fix: “Swap the citation in both places. The validation report does not change — only what the submission says about it.”
- 07The evidence
The lab already tested to the right edition
Dr. Aisha Okonkwo · Test lab leadOne click opens TR-0430, the EO sterilization validation from Lakeview Sterilization Services, dated 21 Jul 2026 and signed, at the passage on page 3. The work was done to the current edition; only the submission's citation was wrong. The report names the sections that cite it and points back to line 22.
TR-0430, p. 3: “This validation was performed in accordance with ISO 11135:2014 + A1:2018 … using the overkill half-cycle approach.”
- 08Standards
Every standard against the edition FDA recognises today
Standards matcherFourteen standards cited, checked against FDA's recognised list refreshed on 12 Oct 2026: one at a withdrawn edition, ISO 11135, and one in a transition period — ISO 10993-1:2018, accepted until 1 Jul 2029 now that FDA partially recognises the 2025 edition. The VLT-Flow 80 can go with 2018; the next biological evaluation should plan for 2025.
The matcher never changes which standard a lab tested to — only the citation.
- 09One click
Swapped in 2 places, and the light turns green
Nadia Brennan · Regulatory affairs specialist, devicesNadia presses “Swap the citation in 2 places”. Section 11, para 2 is swapped and checked again; Section 4, row 7 is swapped and its declaration re-attached; line 22 passes. 31 of 31 checks passed, and 5 sections wait for Marcus Feld's approval and signature.
On the record: “Applied by Nadia Brennan · 13 Oct.”
- 10Signed
He approves, signs — and a person submits
Marcus Feld · Director, Regulatory AffairsNadia sends Sections 4, 8, 9, 11 and 22 to Marcus with a note: preflight green, line 22 fixed, target 20 Oct. Marcus approves the five sections and signs the truthful and accurate statement. The eSTAR PDF is ready to download with its 46 attachments, and Nadia submits it herself through the CDRH Portal.
“Ready to submit · 31 of 31 checks · 22 sections approved · statement signed by Marcus Feld, 13 Oct 14:12. Nadia submits through the CDRH Portal.”